Brand Name : Fullde
Model Number : LB-1800KW-10.5KVAC-J
Certification : CE, ISO9001
Place of Origin : Dongguan,China
MOQ : one set
Price : US $3,000 ~10,000 / Set
Payment Terms : L/C, T/T, Western Union, MoneyGram
Supply Ability : 100 Set/Sets per Month
Delivery Time : 25 working days
Packaging Details : Wooden packaging,Carton packaging
Usage : Auto Testing Machine
Rated Voltage : 110-480 VAC
Connection : Star connection method
Duty Cycle : Continuous
Steps : 450KW/450KW/450KW/450KW
Accuracy : ≤±5%
Type : Pure resistive
Dimension : 6058mm×2438mm×3041 mm
Weight : About 7t
Fullde 1800KW Grey Color Load Bank Test Generator for Middle East
1. Verification Testing
a) Resistor service life: 10 years.
b) Test items are shown in table:
NO | Test item | Standard terms and eligibility criteria |
1 | Appearance | Good appearance, no damage |
2 | Resistance tolerance | <±5% |
3 | Insulation resistance test | < 2MΩ |
4 | Power-Frequency
| The main circuit of the shell processing frequency voltage 2.5KV, last 1min, no breakdown and flashover phenomenon |
5 | Full Load Test | observe equipment running state at full load |
2. Main Configuration Manufacturers
NO. | Items | Manufacturers |
1 | Alloy resistor | Fullde |
2 | Multi-function meter | YIGE |
3 | Fan | Dunli |
4 | Cabinet | Fullde |
5 | Breaker | Schneider/ABB |
3. Technical Parameters
System Composition | Resistor, air cooling, the electric parameters testing, control panel |
Resistor Element | Special alloy resistance, high temperature resistance, corrosion resistance, high precision, long service life, resistance tolerance is ±5%; |
Connection | The three-phase four wire system, star connection method, copper; |
Control | Contactor |
Control Voltage | 3P3W, AC10.5KV; |
Dimension(mm) | 6058mm×2438mm×3041 mm; |
Weight | about 7t |
Load element type | Pure resistive |
Control | Local manual control; |
Load Tolerance | ±5%; |
Way of Working | Continuous working; |
Cooling type | Force air cooling; |
Insulation grade | F; |
Protection | 1. Emergency Stop: User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working; 2. Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload; 3. Fan Air Quantity Protection: when the wind is insufficient, the machine will unload and give alarm; |
Protection Button | there are protection button both in local control and remote control can be switched off when false alarm or for special requirements. |
Transportation | Rings on the top or caster wheels; |
![]() |